Metering pump in the use of noise is what happened? How to solve it?
Cause of trouble 1. the impact sound inside the inlet and outlet check valve
Solution: between the ball valve and valve seat will produce normal impact sound. The larger the one-way valve, the louder the sound
Cause of failure 2. internal pressure relief valve works
Solution:
Check the outlet pressure is abnormal, leading to release valve work
Check whether the inlet line is blocked or not, resulting in the release valve work
Check whether the pressure difference between inlet and outlet of metering pump is insufficient, leading to release valve work
Failure reason 3. internal pressure lubrication system release valve work
Solution: confirm whether the lubricating oil is correct
Sound released by normal pressure
Failure reason 4. worm gear / worm impact between suction and discharge stroke conversion
Solution: check whether the buffer is installed in the outlet pipe and whether the inflation pressure of the buffer is correct
The cause of the trouble is that there is an impact between the suction and the discharge stroke, which results in the collision between the 5. couplings
Solution:
Check the motor steering is correct
Check whether the buffer is installed in the outlet pipe and whether the inflation pressure of the buffer is correct
Failure reason 6. disc elastic gasket failure
Solution: replace dish shaped elastic gasket